HBO 5002 W/NIL
- Microlithography
Because of their high luminance, UV radiation and high internal pressure (when hot) HBO lamps may only be operated in enclosed lamp casings specially constructed for the purpose. Mercury is released if the lamp breaks. Special safety precautions must be taken. More information is available on request or can be found in the leaflet included with the lamp or in the operating instructions.
Technical Data
General Product Information
Product number (Americas)
69116
Product name (Americas)
HBO 5002W/NIL 1/CS 1/SKU
Family brand
HBO
Product remark
Lamp contains overpressure even in cold status - additional safety regulations, supplied with the lamps, have to be fulfilled. Please read Technical bulletin DO-SEM TB 004 carefully
Global order reference
HBO 5002 W/NIL
Electrical Data
Nominal wattage
5000 W
Nominal voltage
33.0 V
Nominal current
152 A
Type of current
DC
Physical Attributes & Dimensions
Electrode gap (cold)
8.0 mm
Diameter
110.0 mm
Diameter (in)
4.331 in
Length
445.0 mm
Length with base excl. base pins/connection
445.00 mm
Connector: presence
Yes
Product weight
2733.00 g
Operating Conditions
Burning position
Other
Environmental & Regulatory Information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Primary article identifier
4008321396235
Declaration no. in SCIP database
3e9390ca-2914-4f60-8a71-81d16b10ba4b
Candidate list substance 1
Lead
CAS No. of substance 1
7439-92-1
Safe use instruction
The identification of the Candidate List substance is sufficient to allow safe use of the article.
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4008321396235 |
VS