IP Protection class
To develop reliable products, it is important to have precise knowledge of the load profiles occurring in later use. With load measurements on location and with real use, relevant environmental and operating loads are measured and analyzed.
The measurement results serve, on the one hand, as a data basis for testing in the laboratory. On the other hand, the reliability of field loads can be evaluated with already-tested products.
Technical specifications | |
Testing room equipment (w x d x h) | (800 x 800 x 975) mm |
Irradiance | 800 to 1200 W/m2 |
Irradiation strategy | 1 piece; 2,5 kW Metal halide emitters |
Temperature test with irradiation | |
Temperature range | -20 °C to +100 °C |
Climate testing with irradiation | |
Temperature range | +15 °C to +80 °C |
Moisture range | 10 % r.F. to 80 % r.F. |
Temperature test without irradiation | |
Temperature range | -30 °C to +100 °C |
Climate testing without irradiation | |
Temperature range | +10 °C to +90 °C |
Moisture range | 10 % r.F. to 90 % r.F. |
Protection class tests against the intrusion of water | |
---|---|
IP X1 | dripping water (perpendicular falling drops) |
IP X2 | dripping water below 15°-angle of casing |
IP X3 | spray water at an angle of up to 60° |
IP X4 | spray water from all directions |
IP X5 | hose water |
IP X6 | intense hose water |
IP X7 | temporary immersion |
IP X8 | enduring immersion |
IP X9k | high pressure and steam-jet cleaning |
Protection class tests against the intrusion of foreign solids | |
---|---|
IP 1X | test probe > ø 50 mm |
IP 2X | test probe > ø 12,5mm |
IP 3X | test probe > ø 2,5 mm |
IP 4X | test probe > ø 1 mm |
IP 5X | dust protected |
IP 6X | dust protected |
Contact
Environment Simulation Laboratory
電話: +49 7324 12-224
An der Bahnbrücke, 89542 Herbrechtingen